After defining formulas, associate parameters used within the formulas.

You can also associate parameters with formulas on the Record View page by clicking Validate Parameters.

  1. Select Work > Inspections > Formulas.

  2. Select the formula for which to associate parameters, and then click the Parameters tab.

  3. Click Add Parameter.

  4. Specify this information:

    Parameter - Specify the parameter with which to associate the formula.

    Formula UOM - Specify the unit of measurement of the formula.

  5. Click Submit.

    Click Validate Parameter to check the accuracy of the SQL statement.