Add equipment to maintenance patterns.

  1. Select Work > WO Planning > Maintenance Patterns.

  2. Select the maintenance pattern for which to add equipment, and then click the Equipment tab.

  3. Click Add Equipment.

  4. Specify this information:

    Equipment - Specify the equipment to add to the maintenance pattern.

    Equipment with logical meters flagged as Up/Down Meter on the Meters page of the equipment record will not be displayed.

    Due Nonconformities Only - Select to include only new observations created for nonconformities that are due for inspection.

    The inspector will not see nonconformities on the work order that are present but not due for inspection. The inspector may be confused if he finds nonconformities during the inspection that were not on the list, which may lead to duplicate nonconformities

    Include Nonconformities - Select to include new observations for re-inspection for existing nonconformities.

    Test Point Set - Specify the test point set for calibration of the equipment.

    Dormant Start - Specify the date on which the dormant period for the PM begins.

    Dormant End - Specify the date on which the dormant period for the PM ends.

    Reuse Dormant Period - Select to use the same specified dormant period for the PM on a yearly basis.

    Date Deactivated - Specify the date after which work order generation stops.

    WO Department - Specify the department of the work order.

    WO Location - Specify the location of the work order.

    WO Cost Code - Specify the cost code of the work order.

    WO Assigned To - Specify the person responsible for the work.

    WO Assigned By - Specify the person assigning the work.

    Work Order Org. - Specify the organization of the work order.

    Due Date - Specify the due date of the first work order.

    Meter #1 Due - Specify the reading due value for the first meter.

    Meter #2 Due - Specify the reading due value for the second meter.

  5. Alternately, click Delete Equipment to delete all equipment records and all awaiting release work orders.

  6. Click Submit.

    • If you populate any of the replacement values (for example, WO Department, WO Location, WO Cost Code, WO Assigned To or WO Assigned By), the default values from the equipment record are replaced when a maintenance pattern work order is created with these replacement values.

    • To activate a maintenance pattern for equipment, click Activate MP.

    • To deactivate a maintenance pattern for equipment, click Deactivate MP.