The Nominal Pipe Diameter Range in the Bolt Commodity Filter sheet is used to create the unique ID definition of the record. Therefore, you must remove the existing record from the catalog by typing D at the beginning of the record. Then, add a new record with the changes. For example, the new requirement dictates that the 1C0031 specification requires the availability of bolts up to 42 inches in size.

  1. Open the Bolt Commodity Filter sheet.

  2. Locate and copy the record.

  3. Type D at the beginning of the first record.

  4. Edit the second record, and then type A at the beginning of the record.

  5. Bulkload the spreadsheet, and review the log file.

  6. Use the Catalog Checker to review the impact of your proposed changes.

  7. Use the Synchronize Model with Catalog Command to mark the out-of-date objects.

  8. Verify your changes, and resolve any discrepancies.

Edit NPD Range Bolt