Define End Preparation Compatibility Exceptions - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
13
  1. Open the Piping Specification Template.xls workbook.

  2. Select the EndPrepCompatibilityExceptionsRule sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Rows.

  4. In the End Preparation End A column, select the end preparation for the port applicable to fitting A. For example, select Small-Groove-Face Lap-Flanged End.

  5. Do one of the following:

    • In the End Standard End A column, define the end standard applicable to the end of fitting A.

    • In the Materials Category End A column, define the classification for the materials grade applicable to fitting A.

      You must define End Standard End A or Materials Category End A.

  6. In the End Preparation End B column, select the end preparation for the port applicable to fitting B.

  7. Do one of the following:

    • In the End Standard End B column, define the end standard applicable to the end of fitting B.

    • In the Materials Category End B column, define the classification for the materials grade applicable to fitting B.

      You must define End Standard End B or Materials Category End B.

  8. In the Joint Requirement column, specify whether the two applicable mating ends are compatible.

  9. In the Connecting Part Short Code column, enter the short code for the coupling or the connector.

  10. In the Connecting Part Commodity Option column, define the commodity option category.

  11. Save the Piping Specification Template.xls workbook.

See Also

End Preparation Compatibility Exceptions Rule