Edit the Flange Thickness in the Piping Generic Data Bolted Sheet - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
13

The Flange Thickness in the Piping Generic Data Bolted sheet is not used to create the unique ID definition of the record. Therefore, you can mark the existing record as modified by typing M at the beginning of the record. For example, the correct flange thickness for 1.25 inch size, 125# pressure rating, flat-face flanged end is 0.5 inches based on the ASME B16.5 standard.

  1. Open the Piping Generic Data Bolted sheet.

  2. Locate the record, edit the Flange Thickness value, and then type M at the beginning of the record.

  3. Bulkload the spreadsheet, and review the log file.

  4. Because editing the Flange Thickness impacts the modeled objects, use the Synchronize Model with Catalog Command to mark the out-of-date objects.

  5. Use the Synchronize Workspace with Catalog Command to update the objects.

  6. Verify your changes, and resolve any discrepancies.

Edit Flange Thickness