Tap End Stud Bolt Calculation Tolerance Rule - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
13

The Tap End Stud Bolt Calculation Tolerance Rule node (the TapEndStudBoltLenCalTol sheet in the Piping Specification.xls workbook) defines the negative or positive tolerance on the bolt length that is used when calculating the tap end stud bolt length. This rule contains all the default values that the software is to use.

Bolt Diameter From (Required)

Type the starting bolt diameter for the tolerance that you want to define. Include the unit indicator of in or mm.

Bolt Diameter To (Required)

Type the ending bolt diameter for the tolerance that you want to define. Include the unit indicator of in or mm.

Bolt Length From (Required)

Type the starting bolt length for the tolerance that you want to define. Include the unit indicator of in or mm.

Bolt Length To (Required)

Type the ending bolt length for the tolerance that you want to define. Include the unit indicator of in or mm.

Bolt Length Tolerance (Required)

Enter the negative or positive tolerance on the bolt length for the bolt length and bolt diameter ranges that you defined. Include the unit indicator of in or mm.

See Also

Piping Specification Rules
Bolt Length Calculations
Bolt Diameter Equivalence Rule
Bolt Extension
Bolt Selection Filter
Bolt Selection Filter for Nozzles
Machine Bolt Length Calculation Tolerance
Preferred Machine Bolt Length
Preferred Stud Bolt Length
Stud Bolt Length Calculation Tolerance