Open the Piping.xls workbook.
-
Select the WeldGapRule sheet.
-
Select a row after the Start keyword but before the End keyword, and click Insert > Rows.
-
In the Spec Name column, type the name of your piping materials class.
-
In the Weld Type column, type the weld type code.
-
Define the NPD range for the weld gap.
-
In the Weld Gap column, type the gap between the welded ends of the welded joint. Be sure to include the units when defining this value, for example, 3mm.
-
Save the Piping.xls workbook.
-
The piping materials class must be defined on the PipingMaterialsClassData sheet.
-
Valid weld type codes are listed in the AllCodeLists.xls workbook on the WeldType sheet in the Codelist Number column.