The Branch Size is used to create the unique ID definition. Therefore, you must delete the existing record, and then add a new record with the change. For example, the new requirement dictates a 3 inch size is available in the pipe specification, instead of a 2.5 inch size.

  1. Open the Pipe Branch Rule sheet.

  2. Locate and copy the record.

  3. Type D at the beginning of the first record.

  4. Edit the second record, and then type A at the beginning of the record.

  5. Bulkload the spreadsheet, and review the log file.

  6. Use the Catalog Checker to review the impact of your proposed changes.

  7. Use the Synchronize Model with Catalog Command to mark the out-of-date objects.

  8. Use the Synchronize Workspace with Catalog Command to update the objects.

  9. Verify your changes, and resolve any discrepancies.