Define Reinforcing Pad Widths - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
13
  1. Open the Piping Specification.xls workbook.

  2. Select the ReinforcingPadData sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Row.

  4. In the Spec Name column, type the name of the piping materials class.

  5. In the Header Size column, specify the header size for the pad width that you are defining.

  6. In the Branch Size column, specify the branch size for the pad width that you are defining.

  7. Define the angle range for the pad width that you are defining.

  8. In the Minimum Reinforcing Pad Width column, enter the minimum reinforcing pad width.

  9. Save the Piping Specification.xls workbook.

The piping materials class must be defined on the PipingMaterialsClassData sheet.

See Also