Define Component Insulation Exclusion - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
13
  1. Open the InsulationData.xls workbook.

  2. Select the ComponentInsulationExclusion sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Row.

  4. In the Piping Commodity Type column, type the codelist number for the piping commodity for which you are defining the rule.

  5. In the First Size From column, specify the beginning first size for the range.

  6. In the First Size To column, specify the ending first size for the range.

  7. In the First Size Units column, specify the units.

  8. In the Heat Tracing Medium column, specify the heat tracing medium codelist number.

  9. In the Insulation Purpose column, specify the insulation purpose codelist number.

  10. Type the insulation temperature range.

  11. Save the InsulationData.xls workbook, and bulkload it into the catalog.

See Also

Component Insulation Exclusion