Define Preferred Tap End Stud Bolt Length - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
13
  1. Open the Piping Specification.xls workbook.

  2. Select the PreferredTapEndStudBoltLength sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Row.

  4. In the Bolt Diameter From column, specify the beginning bolt diameter for the range of bolt diameters that are to use the preferred bolt length.

  5. In the Bolt Diameter To column, specify the ending bolt diameter for the range of bolt diameters that are to use the preferred bolt length.

  6. In the Bolt Diameter Increment column, type the value by which to increment the bolt diameter.

  7. In the Materials Grade column, type the material grade code for the bolt.

  8. Define the preferred bolt length information in the remaining columns.

  9. Save the Piping Specification.xls workbook.

Valid material grade codes are listed in the AllCodeLists.xls workbook on the MaterialsGrade sheet in the Codelist Number column.

See Also

Preferred Tap End Stud Bolt Length Rule