The Calculation Prog IDs node defines the wall thickness and branch reinforcement calculation programs that the software is to use for a design standard.

Design Standard (Required)

Select the design standard for which to assign calculation programs.

Wall Thickness Prog ID (Required)

Specify the Prog ID of the program to use to calculate the wall thickness for this design standard. See Calculation Logic Reference information in the Piping Reference Data.

Branch Reinforcement Prog ID (Required)

Specify the Prog ID of the program to use to calculate the branch reinforcement for this design standard.