Define Outside Surface Treatments - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
13
  1. Open the Piping Specifications.xls workbook.

  2. Select the OutsideSurfaceTreatment sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Row.

  4. In the Nominal Piping Diameter From column, type the nominal pipe diameter (NPD) that specifies the start of the treatment range.

  5. In the Nominal Piping Diameter To column, type the NPD that specifies the end of the treatment range.

  6. In the Nominal Piping Diameter Units column, type the units for the NPDs. For example, type mm or in.

  7. In the Environmental Zone column, specify where the piping is located.

  8. In the Outside Surface Treatment column, select the exterior surface treatment that you want to use for the defined NPD range, if needed.

  9. In the Coating Type column, select the coating type that you want to use for the defined NPD range, if needed.

  10. In the Auxiliary Treatment column, select the auxiliary treatment, if needed.

  11. Save and bulkload the workbook.

  • For more information about each exterior surface treatment property that you can define, refer to Exterior Coating and Surface Treatment.

  • The OutsideSurfaceTreatment sheet in the Piping Specification.xls workbook corresponds to the Exterior Coating and Surface Treatment Rule node in the Catalog task.

See Also

Exterior Coating and Surface Treatment