Define Permissible Taps - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

PPMProduct
Intergraph Smart 3D
aSubProduct
Piping
PPMCategory_custom
Reference Data
Version_SThreeD_Custom
13
  1. Open the Piping Specification.xls workbook.

  2. Select the PermissibleTaps sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Rows.

  4. In the Spec Name column, type the name of your piping materials class.

  5. In the Permissible Tap Number column, enter the tap number that you want to allow in the piping materials class.

  6. In the Is Preferred Tap column, enter TRUE if the tap number is the preferred tap. Enter FALSE if the tap is not the preferred tap.

  7. Save the Piping Specification.xls workbook.

  • The tap numbers must be defined on the Tap Properties.

  • The piping materials class must be defined on the PipingMaterialsClassData sheet.

See Also

Permissible Taps