Define Slip on Flange Setback Distance - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
13
  1. Open the Piping Specification.xls workbook.

  2. Select the SlipOnFlangeSetbackDistance sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Row.

  4. Define nominal piping diameter range for the flange setback distance.

  5. In the Company Practice Gap column, enter the distance between the flange face and the edge of the interior weld.

  6. In the Company Practice Round Off Factor column, enter the value to use to round up the sum of the weld thickness and the gap.

  7. In the End Standard column, type the end standard for the bolted end of the slip-on flange.

  8. In the Maximum Weld Thickness column, type the maximum weld thickness.

  9. Save the Piping Specification.xls workbook.

Valid end standard values are defined in the AllCodeLists.xls workbook on the EndStandard sheet in the Codelist Number column.

See Also

Slip-on Flange Setback Distance