Define NPD Equivalences - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

PPMProduct
Intergraph Smart 3D
aSubProduct
Piping
PPMCategory_custom
Reference Data
Version_SThreeD_Custom
13
  1. Open the Piping Specification.xls workbook.

  2. Select the NPDEquivalence sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Rows.

  4. In the NPD In Primary Units of Measure column, enter the primary nominal pipe diameter.

  5. In the Primary Units of Measure column, type the units for the primary NPD. For example, type mm or in.

  6. In the NPD In Secondary Units of Measure column, enter the secondary nominal pipe diameter.

  7. In the Secondary Units of Measure column, type the units for the secondary NPD. For example, type mm or in.

  8. Save the Piping Specification.xls workbook.

See Also

Nominal Piping Diameter Equivalence Rule