Open the Piping Specification.xls workbook.
-
Select the NPDEquivalence sheet.
-
Select a row after the Start keyword but before the End keyword, and click Insert > Rows.
-
In the NPD In Primary Units of Measure column, enter the primary nominal pipe diameter.
-
In the Primary Units of Measure column, type the units for the primary NPD. For example, type mm or in.
-
In the NPD In Secondary Units of Measure column, enter the secondary nominal pipe diameter.
-
In the Secondary Units of Measure column, type the units for the secondary NPD. For example, type mm or in.
-
Save the Piping Specification.xls workbook.