Edit the Nominal Pipe Diameter Range in the Piping Commodity Filter Sheet - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
13

The nominal pipe diameter range in the Piping Commodity Filter rule is used to create the unique ID definition of the record. Therefore, you must remove the existing record from the catalog by typing D at the beginning of the record. Then, you add a new record with the changes. For example, the new requirement dictates that a 4 inch butterfly valve must be available for the 1C0031 pipe specification.

  1. Open the Piping Commodity Filter sheet.

  2. Locate and copy the record.

  3. Type D at the beginning of the first record.

  4. Edit the second record, and then type A at the beginning of the record.

  5. Bulkload the spreadsheet, and review the log file.

  6. Use the Catalog Checker to review the impact of your proposed changes.

  7. Use the Synchronize Workspace with Catalog Command to mark the out-of-date objects.

  8. Verify your changes, and resolve any discrepancies.

Edit the NPD Range

The corresponding piping part definition and the material control data for the new optional contractor commodity code must exist in the catalog.