Define Field Fit Lengths - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

PPMProduct
Intergraph Smart 3D
aSubProduct
Piping
PPMCategory_custom
Reference Data
Version_SThreeD_Custom
13
  1. Open the Piping Specification.xls workbook.

  2. Select the FieldFitLength sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Row.

  4. In the Weld Type column, enter the weld type code for which to define a field fit length.

  5. Specify the NPD range for the field fit length.

  6. Specify the constructions requirements.

  7. In the Field Fit Length column, enter the field fit length. Be sure to include the units of measure, for example in or mm, when specifying this value.

  8. Save the Piping Specification.xls workbook.

Refer to Field Fit Length for more information about the columns in this sheet.

See Also

Field Fit Length