The Root Gap Per Spec rule node (the RootgapPerSpec sheet in the Sample Data Piping Specification.xls workbook) is an optional rule that defines the root gap to apply to the weld between the header pipe and an olet-type branch, or between an elbow and an elbolet. The information defined here is the exceptions per piping materials class to the root gap information defined on the Root Gap Rule.

Nominal Piping Diameter From (Optional)

Define the lower bound of the header's largest nominal piping diameter for which this root gap applies.

Nominal Piping Diameter To (Optional)

Define the upper bound of the header's largest nominal piping diameter for which this root gap applies.

Nominal Piping Diameter Units (Optional)

Specify the units for the Nominal Piping Diameter From and Nominal Piping Diameter To columns. For example, type in for inches or mm for millimeters.

Root Gap (Required)

Specify the root gap to use for the nominal piping diameter range. Be sure to include the units of measure when specifying this value.

Spec Name (Required)

Type the name of the piping material class for which you are defining the root gap information. The piping materials class that you enter must be defined on the Piping Materials Classes.

See Also

Piping Materials Class Rules
Define Root Gaps Per Spec