Define Size Reduction Rule - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
13
  1. Open the Sample Data Piping Specification.xls workbook.

  2. Select the SizeReduction sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Rows.

  4. Enter the reduction type. Type 1 for concentric reducers. Type 2 for eccentric reducers.

  5. Enter the first and second sizes for the size reduction rule.

  6. Enter the second fitting's first size.

  7. Optionally, enter the third and fourth fittings' first size.

  8. Optionally, enter the size reduction preference order.

  9. Save the Sample Data Piping Specification.xls workbook.

See Also

Size Reduction Rule