  1. Open the Sample Data Piping Specification.xls workbook.

  2. Select the SizeReduction sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Rows.

  4. Enter the reduction type. Type 1 for concentric reducers. Type 2 for eccentric reducers.

  5. Enter the first and second sizes for the size reduction rule.

  6. Enter the second fitting's first size.

  7. Optionally, enter the third and fourth fittings' first size.

  8. Optionally, enter the size reduction preference order.

  9. Save the Sample Data Piping Specification.xls workbook.