Edit the Maximum Temperature in the Piping Commodity Filter Sheet - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

PPMProduct
Intergraph Smart 3D
aSubProduct
Piping
PPMCategory_custom
Reference Data
Version_SThreeD_Custom
13

The Maximum Temperature attribute in the Piping Commodity Filter rule is used to create the unique ID definition of the record. Therefore, you must remove the existing record from the catalog by typing D at the beginning of the record. Then, add a new record with the changes. For example, the new requirement dictates that you can place small ball valve sizes in the 1C0031 pipe specification if the pipe run maximum temperature is less than or equal to 400 degrees F.

  1. Open the Piping Commodity Filter sheet.

  2. Locate and copy the record.

  3. Type D at the beginning of the first record.

  4. Edit the Maximum Temperature of the second record, and then type A at the beginning of the record.

  5. Bulkload the spreadsheet, and review the log file.

  6. Use the Catalog Checker to review the impact of your proposed changes.

  7. Use Synchronize Model with Catalog to mark the out-of-date objects.

  8. Verify your changes, and resolve any discrepancies.

Edit Max Temperature