  1. Open the Piping Specification Template.xls workbook.

  2. Select the NPDCompatibilityExceptionsRule sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Rows.

  4. In the Nominal Piping Diameter1 column, enter the nominal pipe diameter for the end of the applicable joint that represents End A.

  5. In the Nominal Piping Diameter1 Units column, type the units for the nominal piping diameter that you entered for Nominal Piping Diameter1. For example, type mm or in.

  6. In the Nominal Piping Diameter2 column, enter the nominal pipe diameter for the end of the applicable joint that represents End B

  7. In the Nominal Piping Diameter2 Units column, type the units for the nominal piping diameter that you entered for Nominal Piping Diameter2. For example, type mm or in.

  8. Save the Piping Specification Template.xls workbook.