Reinforcing Pad Data - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Piping Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Reference Data
Smart 3D Version
13

The Reinforcing Pad Data node (the ReinforcingPadData sheet in the Piping Specification.xls workbook) defines the minimum reinforcing pad width to use in branch reinforcement calculations based on the header and branch size and the acute angle of the intersection between the header and the branch.

Acute Branch Angle From (Required)

Enter the branch angle lower bound for which the reinforcing pad data applies. Be sure to include the unit of measurement when specifying this value.

Acute Branch Angle To (Required)

Enter the branch angle upper bound for which the reinforcing pad data applies. Be sure to include the unit of measurement when specifying this value.

Branch Size (Required)

Enter the branch size for which the reinforcing pad data applies.

Branch Size Units of Measure (Required)

Specify the units of measurement, in or mm for example, of the value you entered in the Branch Size column.

Header Size (Required)

Enter the header size for which the reinforcing pad data applies.

Header Size Units of Measure (Required)

Specify the units of measurement, in or mm for example, of the value you entered in the Header Size column.

Minimum Reinforcing Pad Width (Required)

Enter the minimum width of the reinforcing pad. Be sure to include the units of measurement, in or mm for example, when specifying this value.

Spec Name (Required)

Type the name of the piping materials class for which to define the reinforcing pad data. The piping materials class that you enter must be defined on the Piping Materials Classes.

See Also

Piping Materials Class Rules
Field Fit Length
Reinforcing Weld Data
Weld Clearance Rule
Weld Gap Rule
Weld Model Representation Rule
Weld Type Rule
Define Reinforcing Pad Widths