When you save the details entered in the filtering setup grids, the software creates the appropriate table detail links on the Table Details screen.
Project Setup
-
Click SRD > XS20 Spec > XS2010 Project Setup.
-
Under Filter Group Labelling, assign a master table for a filter group..
-
Under Filter Setup, assign tables to that filter group/area, and select the Table Detail Link Ind check box for some of the tables.
Specification
-
Click SRD > XS20 Spec > XS2020 Spec Editor.
-
In a specification, on the Cover page, enter details in the filter group/area and tables that you worked with in the Project Setup procedure above.
-
Save the specification.
The software creates the table detail link on the Table Details screen.
The table name is from the table associated with the filter group/area. The group name is ALL1 by default.
-
When you update the details for the tables in a specification, the software creates a new set of table detail links.
-
When you delete a row from the specification filter default, it has no impact on the existing table detail links.
-
When you clear the Table Detail Link indicator for a table, the software deletes the details for that table on the Table Details screen.
-
When you change the master table name for a filter group on the Project Setup dialog box > Filter Group Labelling, there is no change to existing table details and links if they already exist for the former table name.
-
Updating the table name for a filter group/area on the Project Setup dialog box > Filter Setup is not possible if table details already exist for that table.