Click Integration > XI10 SPIso > XI1030 Export > XI103020 Export Jobs.
-
In the upper grid, click Edit Grid .
-
Click Add Row .
-
Type a job name in the Job Code box.
-
(Optional) Change the number in the Run Number box if necessary. This value is set to 1 by default.
-
Select a pre-defined export definition set from the Selection list in the Export Definition Set box.
-
(Optional) Delete or update the Bore Unit and Dim Unit values if necessary. These values are copied from the symbol key set entries.
-
(Optional) In the Comment box, type any text about the export job.
-
Click Save Grid in the upper grid.
-
Click Read-Only Grid in the upper grid.
-
In the lower grid, click Edit Grid .
-
Click Add Row .
-
In the Spec Code box, use the Selection list to select a specification.
The Selection list on the Export Jobs screen is restricted depending on the project default ZX_ALLSPEC (only issued specs are shown or all specs are shown). In addition, product group specs are only visible in the project if they have been released on A.20.10.
-
Click Save Grid in the lower grid.
-
The Status, Start User, Start Date, End Date, and Job Summary boxes are populated by the job procedure and cannot be updated by the user.
-
The selected SKEY set in the tree on the left determines which set should apply to export processing. For more information, see Define symbol key sets.
-
An export job can contain more than one specification. For each specification, a separate .mdb file is created.
-
To create a new export job from an existing job, select the existing export job, and click New Run at the top. A new export job is created from the selected job, with an incremented Run Number value.