Skirt Comp. Allowable Mult. for (B) at Base (OPE) - PV Elite - Help - Hexagon

CodeCalc Help

Language
English
Product
PV Elite
Search by Category
Help

Enter the factor to be multiplied plied by the Code compression allowable B for the operating case. The software will look at the minimum of this factor times its allowable and the skirt yield stress times its allowable multiplier. This minimum value will then be used as a comparison to the actual compressive stress in the skirt.