Nominal Pipe Size of Half-Pipe Jacket - PV Elite - Help - Hexagon

CodeCalc Help

Language
English
Product
PV Elite
Search by Category
Help

Enter the nominal pipe size of the half-pipe jacket. The pipe size entered must lie within the range of values supported in ASME Section VIII, Div. 1, Appendix EE. The supported sizes range between NPS 2 inch and NPS 4 inch.

Click to open the Pipe Selection Dialog Box and select the appropriate material. The Pipe Selection Dialog Box displays read-only information about the selected material.

If working in SI units, the proper conversion values must be entered. For example, if working with a NPS 50 pipe, the corresponding SI value of 5.08 cm must be entered. The following table lists the accepted values for the NPS.

English Input NPS

NPS

SI

2.0 in

50

5.08 cm

2.5 in

65

6.35 cm

3.0 in

80

7.62 cm

3.5 in

90

8.89 cm

4.0 in

100

10.16 cm