Reviewing the Results - The Output Option - PV Elite - Help - Hexagon

CodeCalc Help

Language
English
Product
PV Elite
Search by Category
Help

You can quickly review the results of this analysis using the Output option. On the Home tab, click Review Result. If you have analyzed the components from the input, CodeCalc automatically displays the output for you. You see the following dialog box:

There are three analyses in the output file. If you perform additional analysis runs, or analyze other components, such as nozzles, flanges, and tubesheets, the additional analyses also display. This allows you to review (and print) all of the calculations that you have done for a given vessel or job at one time. The individual report can be viewed by selecting one of the items in the report area.

You can scroll up and down in the text to see all input data and results. The Summary of Internal Pressure Results shows that the required thickness is less than the actual thickness for this job, while the maximum allowable working pressure (MAWP) is greater than the design pressure. Therefore, the shell thickness you selected is acceptable.

You can select more than one analysis at a time by holding down the CTRL key while selecting the items to view. You can select all reports by clicking Edit > Select All. When viewing the reports, click Next Report to move to the next component.