Select Re-Pad when the nozzle has a pad. Select None if there is no pad. For FEA only, select Hub when the nozzle has a hub reinforcement.

For WRC 107/537, the software performs two separate analyses:

  • Using the nozzle OD and the vessel wall thickness plus the reinforcing pad thickness

  • Taking the pad into account by making the nozzle OD equal to the reinforcing pad diameter and assuming a solid attachment.