Basic Quality Factor for Longitudinal Joints - PV Elite - Help - Hexagon

CodeCalc Help

Language
English
Product
PV Elite
Search by Category
Help

The basic quality factor is used in the wall thickness calculations for pipes under internal pressure only. These factors are listed in the ANSI B31.3 piping code Table A-1B. For seamless and fully radiographed pipe, this value is 1.0. For electric resistance welded and spot welded materials it is usually 0.85.