To connect two conduit runs using Move :

  • For inline connections, the two conduit ends must be collinear to each other.

  • For branch connections, the header and branch runs must be orthogonal to each other.

  • There should be sufficient space at the connection to accommodate the connecting part. If the space is not sufficient, the software does not make a connection and displays a message suggesting that you connect the conduit runs manually.

  • The software consumes the first available straight feature of the moved conduit run to accommodate the connection thickness, such as a mating part.

  • In a partial move, if the connection results in an overlap the software connects the two ends with a To Do Record to maintain the connectivity.

  • If there is no space to accommodate mating part, the software does not connect the two ends and displays a message suggesting that you to connect the ends manually.

Inline Connection

No.

Route Object

Approval Status

Permission Group Access

1

Conduit run A

Working

Full control/ Write

2

Conduit run B

Working

Full control/ Write

3

Connection

Result: The software connects the conduits A and B.

No.

Route Object

Approval Status

Permission Group Access

1

Conduit run A

Working

Full control/ Write

2

Conduit run B

Working

Full control/ Write

3

Transition mating part connecting the conduits

Result: The software connects the conduits A and B using a mating reducer. Reduction in conduit B length = connection thickness.

Branch Connections

No.

Route Object

Approval Status

Permission Group Access

1

Header run

Working

Full control/ Write

2

Branch run

Working

Full control/ Write

3

Horizontal tee connection associated with the header

Result: The software connects the header and branch runs at the tee end feature.

Equipment Connection

No.

Route Object

Approval Status

Permission Group Access

1

Conduit run

Working

Full control/ Write

2

Equipment

Working

Full control/ Write

3

Coupling connection

Result: The software connects the conduit run and equipment at the conduit port on the equipment.