You can link directly to this document using https://docs.hexagonppm.com/go/S3D11Elec
The following changes have been made to the Electrical task.
Hotfix and Service Pack Updates
-
You can now extend a conduit or group of conduits from a duct bank. See Move a conduit end feature from a duct bank. (P2 CP: 342049)
-
Added a new Minimize the cable tail lengths option to AutoRoute Options Dialog. See AutoRoute. (P2 HF:309950)
-
Added information about free leg behavior. See Free Leg in Rules for Moving Route Objects. (P2 CP:319923)
Version 2016 (11.0)
-
Updated the Cable Schedule Dialog with new commands to review the retrieved cables.
-
You can now move or delete objects at boundary connections while maintaining the electrical design intent. See Moving at Boundary Connections and Deleting at Boundary Connections. (P2 CP:249685, P2 CP:267185, P2 CP:268379, P2 CP:264940, P2 CP:248568; CP:300832)
-
Added a new Disconnect command that allows you to disconnect route objects without disturbing the rest of the network. (P2 CP:293435)
-
You can slide a branch leg along a header run without disconnecting the branch. See Move a cableway branch and Move a conduit branch. (P2 CP:293434)
-
You can now select a straight feature on a run, and move the feature to connect the run to an adjacent run. See Move a set of cableway features and Move a set of conduit features. (P2 CP:300832)
-
You can select a section of electrical network using the new Route Selection Commands. (P1 CP: 248690, P2 CP:293434, P1 CP:297357)
-
Added a new Quick Route Command command that enables you to join two existing cableway segments or conduit segments. (P1 CP:248716; P1 CP:248717; P3 CP:288004; P3 CP:290874; P3 CP:290886; P2 CP:291085)
-
Added a new locate filter, Construction Graphics. See Edit properties. (P2 CP:271166)
-
You can now select cable tray partitions using the Enclosed Runs option in the Locate Filter. To select an entire cable tray run, use the Enclosing Runs option. You can add barriers to an existing cable tray. You can also modify, and delete the partitions of a cable tray. See Cable Trays. (P2 CP:186222)
-
You can now select conduits in a duct bank using the Enclosed Runs option in the Locate Filter. To select an entire duct run, use the Enclosing Runs option. You can also move or delete the Duct Banks along with its conduits. (P3 CP:276232)
-
You can now set the software to remember the last used working plane when routing cableway or a conduit. See Defaults Tab (Cableway Settings Dialog) and Defaults Tab (Conduit Settings Dialog). (P4 CP:258470)
-
You can now defer cable length and tray fill calculations while performing cableway network modifications. See Edit Cableway Straight Feature Ribbon and Edit Cable Path Ribbon. (P2 CP:370519)