Displays and defines the general properties of the selected conduit end feature.

Standard

System

Displays the system to which the end feature belongs. You cannot change the system of the end feature.

Conduit Run

Displays the conduit run to which the end feature belongs.

Specification

Displays the active conduit specification for the end feature.

Nominal Conduit Diameter

Displays the nominal diameter (NCD) of the end feature. If appears in the box, the NCD for the end feature is inherited from the conduit run to which the end feature belongs.

Type

Displays the types of end features allowed by the selected Specification and Nominal Conduit Diameter. End features are listed by short codes. You can change the end feature type if needed. If you have manually selected the part, this box displays Part selected manually and cannot be changed.

Option

Displays a list of available end features. The software generates this list based on the conduit specification, the NCD, and the short code that you selected in the Type box. If you have manually selected the part, this box displays Part selected manually and cannot be changed.

Base Part Name

Displays the part name for the end feature. The software selects the part number using the conduit specification guidelines.