General Tab (Conduit Turn Feature Properties Dialog) - Intergraph Smart 3D - Help

Intergraph Smart 3D Electrical

Language
English
Product
Intergraph Smart 3D
Subproduct
Electrical
Search by Category
Help
Smart 3D Version
11 (2016)
SmartPlant Foundation / SDx Version
10

Displays and defines the general properties of the selected conduit turn feature.

Standard

System

Displays the system to which the turn feature belongs. You cannot change the system of the turn feature.

Conduit Run

Specifies the conduit run to which the turn feature belongs. Other runs in the same system as the original conduit run display for selection.

Specification

Specify the active conduit specification for the turn feature. All conduit specifications that are allowed for the system parent of the conduit run display for selection. If appears in the box, the conduit specification is inherited from the conduit run to which the turn feature belongs. If the icon does not appear and you want to use the conduit specification from the conduit run, select Use Run Specification.

Nominal Conduit Diameter

Specify the nominal diameter (NCD) of the turn feature. If appears in the box, the NCD for the turn feature is inherited from the conduit run to which the turn feature belongs. If the icon does not appear, and you want to use the conduit specification from the conduit run, select Use Run NCD. If you have manually selected the part, the NCD of the selected part appears and cannot be changed.

Type

Displays the types of turn features allowed by the selected Specification and Nominal Conduit Diameter. Turn features are listed by short codes. You can change the turn feature type if needed. If you have manually selected the part, this box displays Part selected manually and cannot be changed.

Option

Displays a list of available turn features. The software generates this list based on the conduit specification, the NCD, and the short code that you selected in the Type box. If you have manually selected the part, this box displays Part selected manually and cannot be changed.

Base Part Name

Displays the part name for the turn feature. The software selects the part number using the conduit specification guidelines. Click Select Manually to override the conduit specification, and select the part number from the catalog. If you select a part manually, the Nominal Conduit Diameter, Type and Option properties are disabled.

Fill Information

Percent Fill

Displays or defines the percent cable fill in the conduit feature.