SG-1005 CLONE - Databridge - SyncMaintenanceOrder BOD is using default WO type value instead of user code for WO Type - HxGN EAM - Version 12.0 - Hexagon

HxGN EAM Resolved Issues for 2022

Language
English
Product
HxGN EAM
Search by Category
HxGN EAM Version
12

SG-1005 CLONE - Databridge - SyncMaintenanceOrder BOD is using default WO type value instead of user code for WO Type

 Description 

DATABRIDGE IMPACT NOTE:

Modification is made in inbound MaintenanceOrder BOD so that the user code of wo type will be calculated from incoming system wo type(MaintenanceOrderHeader\\Classification\\Codes\\Code\[@listID="Maintenance Order Types"]) only when incoming user code of wo type(MaintenanceOrderHeader\\Classification\\Codes\\Code\[@listID="WorkType"]) is null. Before the modification, the incoming user code of wo type is ignored when the incoming system wo type is provided in BOD.

END OF DATABRIDGE IMPACT NOTE

# Create new work order type using user code of Project with the system code of BR

# Send SyncMaintenanceOrder BOD outbound from EAM and inbound to another EAM environment.

Expected Result - Work order is created with user code of Project

Actual Actual Result - Work order is created using WO type of Breakdown