Option Switch 41: Bore/Dimension/Weight Control - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Controls output of bore, dimensional units, and dimension styles, including stacked fractions. This option switch is also used to determine how the numeric part of a metric coordinate is formatted. Finally, you can use this option switch to control component weight output. You can specify weight per unit length in units different from those used on the isometric drawing.

  • Units for bore and weight data included in the input pipeline data file are set by Option Switch 65.

  • Bolt length and bolt diameter units defined by Option Switch 41 can be modified by using Option Switch 65.

Switch Settings

The following settings are available for Option Switch 41:

SWITCH POSITION 1 - Dimensional Units Type

0

Output pipeline bores in inches and linear dimensions in millimeters (Mixed or SI units). This is the default setting.

1

Output pipeline bores in inches and linear dimensions in feet and inches (Imperial units).

2

Output pipeline bores and linear dimensions in millimeters (Metric units).

3

Output pipeline bores in millimeters and linear dimensions in millimeters (Mixed units).

SWITCH POSITION 2 - Coordinate Output Format (Metric Coordinates Only)

0

Output metric dimensions and coordinates in millimeters.

1

Output metric dimensions in millimeters and coordinates in meters (M.mmm)

2

Output metric dimensions in meters (M.mmm) and coordinates in millimeters.

3

Output metric dimensions and coordinates in meters (M.mmm).

4

Output metric dimensions in millimeters and coordinates in 10th millimeters.

5

Output metric dimensions in 10th millimeters and coordinates in millimeters.

6

Output metric dimensions and coordinates in 10th millimeters.

SWITCH POSITION 3 - Feet/Inch Output and Stacked Fractions

0

Output standard FT/IN dimensions, as in 6' 10.3/8".

1

Output standard FT/IN dimensions and include a dash, as in 6' - 10.3/8".

2

Output standard FT/IN dimensions using a blank space instead of a period (.) between inches and fractions of an inch, as in 6' - 10 3/8".

3

Output stack fractions with a dash (-), as in 6' - 10 3/8"

4

Output stacked fractions without a dash (-), as in 6' 10 3/8".

5

Output decimal inches to 1 decimal place.

6

Output decimal inches to 2 decimal places.

7

Output decimal inches to 3 decimal places.

8

Output decimal inches to 4 decimal places.

SWITCH POSITION 4 - Weight Information Output / Weight Units

0

Suppress output of weight information. This applies to all outputs, including material lists, weight output on drawing frame, material control files and so forth. This is the default setting.

1

Input/output all weights in kilograms (kgs).

2

Input/output all weights in pounds (lbs).

3

Input/output all weights in kilograms/meters (kgs/m).

4

Input/output all weights in pounds/meters (lbs/m).

5

Input/output all weights in kilograms/feet (kgs/ft).

6

Input/output all weights in pounds/feet (lbs/ft).

SWITCH POSITION 5 - Component Weight Output

0

Suppress output of component weight on the material list. This is the default setting.

1

Output any component weight as a total weight (quantity x unit weight).

2

Output any component weight as the individual weight of each component type (no multiplication x quantity).

SWITCH POSITIONS 6 & 7 - Imperial Dimension Output Format (Inches or Feet-Inches)

0

Change dimension output format from inches to feet-inches at 24". For example, 28" is output as 2' 4".

1

Output dimensions in inches.

Value

Change dimension output format as specified. Set the value to a number of whole inches. Acceptable values are 12 or greater.

SWITCH POSITION 8 - Suppression of Bore (Nominal Size) Output at Branch (Tee/Olet/Cross) and Reducer Locations

0

Output nominal size information at branches and reducers.

1

Suppress output of nominal size information at branches and reducers.

SWITCH POSITION 9 - Nominal Size Output Separately on Pipe Section for Set-on Tees and Crosses

0

Output nominal size on set-on tees and crosses combined.

1

Output nominal size on set-on tees and crosses separately.

Switch Layout


Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 61 - Weight Output Facility

7.0.0

OCT 1993

Dev. No. 64 - External Weight / C of G

7.2.0

APR 1995

7.4.0 Release Notes

7.4.0

DEC 1995

7.17.7 Release Notes

7.17.7

MAY 1999

Dev. No. 83F - Dimensioning Enhancements

8.5.4

DEC 2000

8.11.0 Release Notes

8.11.0

APR 2003

Dev. No. 91D - Unit Conversion

8.13.0

SEP 2006

Related Option Switches

Option Switch 65: Bolting Units

Option Switch Detail Sketch

Bore/Dimension/Weight Control (OS 41)