Option Switch 113: Material Control (Pipeline Identification) - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Controls the format of the pipeline reference (that is, the name) that is passed to the Isogen Material Control Transfer (MATC) file.

Switch Settings

The following settings are available for Option Switch 113:

0

Pass the full pipeline reference as contained in the pipeline reference record. For example, pipeline reference 6-LNG-6412A-CT5 in the design database remains the same in the MATC file. This is the default setting.

1


Formulate a revised pipeline reference by stripping off the characters outside the first and last delimiting character (-) of the pipeline reference, removing the central delimiter (-), and then passing the remaining character string. For example, pipeline reference 6-LNG-6412A-CT5 is changed to LNG6412A in the MATC file.

This is a specific facility. It will not function if the pipeline reference in the pipeline input data file is not in the exact form as described above.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Related Option Switches

N/A

Option Switch Detail Sketch

N/A