Option Switch 32: Drawing Output (Scaling) - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Allows the increase or decrease of the final plotted isometric size, and thus changes it from what is defined by Option Switches 14, 15, and 16.

Switch Settings

The following settings are available for Option Switch 32:

0 to 100

Allows no change in scaling and generates an isometric drawing at the size defined either by Option Switch 14 or by a combination of Option Switches 15 and 16.

Value

Increases or decreases the final isometric size in the ratio of Value/100. For example, a value of 71 generates a drawing at 71% of the original size; a value of 120 generates a drawing at 120% of the original size.

Switch Layout

 Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

6.0 Release Notes

6.0.0

MAR 1991

Related Option Switches

Option Switch 14: Drawing Size (Standard PostScript Plotter Size)
Option Switch 15: Drawing Size (Height)
Option Switch 16: Drawing Size (Width)

Option Switch Detail Sketch

Drawing Output - Scaling (OS 32)