Controls the plotting of names/tags on most pipeline components. Tagging of pipe (tube) and pipeline elements made from pipe (tube) is not supported. Tagging of instruments is controlled by Option Switch 123. Names/ tags may be switched on or off to suit your requirements. A secondary option when plotting names/tags is to have the text boxed-in with a surrounding enclosure.
Switch Settings
The following settings are available for Option Switch 60:
SWITCH POSITION 1 - Plotting of Component Names / Tags
0 |
Suppresses the plotting of names / tags. This is the default setting. |
1 |
Plots and boxes in names / tags. |
2 |
Plots, but does not box in, names / tags. |
SWITCH POSITION 3 - Component Names / Tags Enclosures
0 |
Enclose component names / tags in a square-ended box. |
1 |
Enclose component names / tags in a diamond-ended box. |
2 |
Enclose component names / tags in a round-ended box. |
3 |
Enclose component names / tags in a triangular shape. |
4 |
Enclose component names / tags in a diamond shape. |
5 |
Enclose component names / tags in a square-ended box. |
6 |
Enclose component names / tags in a circular shape. |
7 |
Enclose component names / tags in an elliptical shape. |
8 |
Enclose component names / tags in a hexagonal shape. |
Switch Layout
Related Program Development Specifications |
Version |
Date |
Introduced |
1.0.0 |
APR 1983 |
Dev. No. 32 - Extension of Component Naming Facility |
5.5.0 |
FEB 1988 |
8.13.0 Release Notes |
8.13.0 |
SEP 2006 |
Related Option Switches |
||
Option Switch 64: Pipe Support Identification |
||
Option Switch Detail Sketch |
||