Controls the plotted length of a ghost gap element. A ghost gap element is a physical gap on the plotted isometric drawing that can be used when generating individual pipeline isometric drawings, or used as a link between related but unconnected pipelines on a system-type isometric drawing.
Switch Settings
The following settings are available for Option Switch 110:
0 |
Use the normal minimum gap as controlled by Isogen. This is the default setting. |
Value |
Use the user-defined minimum gap dimension, where Value represents the user-defined value in whole mm. The range of value allowed is 18-66. The software will use the appropriate maximum value if a value outside the limits is detected. |
Switch Layout
Related Program Development Specifications |
Version |
Date |
Introduced |
1.0.0 |
APR 1983 |
Dev. No. 47 - Ghost Gap Facility |
5.9.0 |
MAR 1990 |
Related Option Switches |
||
N/A |
||
Option Switch Detail Sketch |
||