Controls whether equipment nozzle indicators are plotted (in dotted line style) on the isometric drawing. Also controls the calculation of nozzle axis directions and insertion of this information into the Piping Component File (PCF) when using PCFGEN.

Switch Settings

The following settings are available for Option Switch 111:

SWITCH POSITION 1 - Dotted Nozzle Indication

0

Suppress dotted nozzles. This is the default setting.

1

Enable dotted nozzles to be plotted on the isometric drawing.

SWITCH POSITION 2 - Nozzle Axis Direction Calculation

0

Disable calculation of the nozzle axis direction.

1

Calculate the nozzle axis direction and insert the information into the PCF.