Option Switch 65: Bolting Units - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Determines how bolts are reported on the material list and in the material control file in terms of diameter and length. This option switch also determines whether bolts are included in the material control file.

Switch Settings

The following settings are available for Option Switch 65:

SWITCH POSITION 1 - Bolt Length Units and Material Control File Options

0

Follow the setting defined by Option Switch 41. This is the default setting.

1

Report bolt length in inches.

2

Report bolt length in millimeters.

3

Exclude bolts from the material control file. Normally, bolts are included.

SWITCH POSITION 2 - Bolt Diameter Units

0

Follow the setting defined by Option Switch 41. This is the default setting.

1

Report bolt diameter in inches.

2

Report bolt diameter in millimeters.

SWITCH POSITION 3 - Allow Bolts to be Excluded from the Material Control File

0

Output bolts to the material control file.

1

Exclude bolts from the material control file.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 56 - User-Defined Material List

7.0.0

OCT 1993

 8.11.0 Release Notes

8.11.0

APR 2003

Related Option Switches

Option Switch 41: Bore/Dimension/Weight Control

Option Switch Detail Sketch

Bolting Units (OS 65)