Option Switch 77: Weld Number Allocation at Slip-On Flanges and RPads - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Controls the quantity of weld numbers generated by the program at slip-on flange and reinforcement pad (RPad) positions. Reinforcement pads can also control the optional generation of an item code or material description on the material list and the plotting of the pad shape.

Switch Position 3 controls the automatic generation of an item code and material description on the material list and a plotted shape for the pad on the isometric.

Reinforcement pads may optionally exist on set-on tees or crosses and on trunnion-type pipe supports.

Switch Settings

The following settings are available for Option Switch 77:

SWITCH POSITION 1 - Quantity of Weld Numbers Generated at Slip-On Flanges

0

Use two weld numbers. This is the default.

1

Use one weld number.

2

Use two weld numbers.

SWITCH POSITION 2 - Quantity of Extra Weld Numbers Generated at Reinforcement Pads

0

Display no extra weld numbers.

1

Display one extra weld number.

2

Display two extra weld numbers.

These are extra weld numbers because they are created in addition to the normal single and double-branch connection weld numbers that are generated at set-on tee and cross positions.

SWITCH POSITION 3 - Reinforcement Pads

0

Generate no item code, material description, or plotted pad shape.

1

Generate an item code, material description, and plotted pad shape automatically.

SWITCH POSITION 4 - Allocation of Weld Numbers on Fabricated "Y" Types

0 or Blank

Display one extra weld number.

1

Display one extra weld number.

2

Display two extra weld numbers.

SWITCH POSITION 5 - Allocation of Weld Numbers on Tack Welds

0 or Blank

Display no extra weld numbers.

1

Display one extra weld number.

SWITCH POSITION 6 - Allocated for Future Use

SWITCH POSITION 7 - Allocation of Weld Number to Victaulic Welded/Forged Ring Type Clamps (CLVR)

0

Allocate two numbers to the Victaulic Clamp.

1 to 9

Allocate specified numbers to the Victaulic Clamp.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 65G - Weld Numbers at Reinforcement Pads

7.4.0

DEC 1995

Dev. No. 70 - New Style Mutli-way Fittings

7.13.0

FEB 1998

Dev. No. 89E - Connection Enhancements

8.10.0

MAY 2002

Related Option Switches

Option Switch 53: Weld Numbering
Option Switch 54: Weld Plotting
Option Switch 75: Weld Number (Enclosure Weld Number/Weld Number - Prefix)

Option Switch Detail Sketch

Weld Number Allocation at Slip-on Flanges and RPads (OS 77)