Controls the required isometric type.
Switch Settings
The following settings are available for Option Switch 21:
SWITCH POSITIONS 1 and 2 - Isometric Type
0 |
Generate a combined isometric drawing, which contains a combination of fabrication, erection, and offshore information as appropriate. This is the default setting. |
1 |
Generate an erection/offshore isometric drawing. |
2 |
Generate a fabrication only isometric drawing. |
4 |
Generate individual flat spool isometric drawings (maximum legs flat). |
5 |
Generate individual flat spool isometric drawings (maximum legs parallel). |
6 |
Generate individual spool isometric drawings (as-built orientation). |
7 |
Suppress isometric drawing generation. |
10 |
Generate a combined material list without pipeline graphics. |
11 |
Generate an erection material list without pipeline graphics. |
12 |
Generate a fabrication material list without pipeline graphics. |
16 |
Generate a spool material list without spool graphics. |
SWITCH POSITION 3 - Test Isometric
0 |
Generate a normal isometric drawing. |
1 |
Generate a test isometric drawing with all dimensions and material list quantities output as Xs. Do not decrement the hardware lock count. |
8 |
Increase tolerance to join disconnected components. Set to 8 mm. |
9 |
Produce separate drawings for disconnected pipeline when increased tolerance is used and Option Switch 55 Position 3 is set to 0. |
Values 8 and 9 are set internally and do not require you to take any action. When a minor break occurs at the bypass closure point, IDFGEN sets switch position 3 to 8 so that Isogen will still recognize the bypass situation that has been created. IDFGEN sets switch position 3 to a value of 9 when certain conditions of Option Switch 55 are met. In these situations, Isogen outputs a disconnected pipeline message when necessary.
SWITCH POSITION 4 - Isometric Style
0 |
Generate a piping isometric drawing. |
1 |
Generate a tracing isometric drawing. |
Switch Layout
Related Program Development Specifications |
Version |
Date |
Introduced |
1.0.0 |
APR 1983 |
Dev. No. 63 - Flat Spools Facility |
7.1.0 |
JUN 1994 |
Dev. No. 63A - Isometric Test Facility |
7.4.2 |
JAN 1996 |
Dev. No. 74A - Disconnected Pipelines |
7.16.0 |
MAY 1999 |
Dev. No. 91L - Heat Tracing |
8.12.0 |
FEB 2005 |
Related Option Switches |
||
N/A |
||
Option Switch Detail Sketch |
||