Controls the physical length of the plotfile that is generated by Isogen. This switch is necessary only when you use the Multiple Isometrics In Each Plotfile option (Option Switch 31= 0), and the required plotfile length is different from the default value of 3275 millimeters (mm).
Switch Settings
The following settings are available for Option Switch 1:
SWITCH POSITIONS 1, 2, 3 and 4
0 |
Set the plotfile length to 3275mm. This is the default setting. |
Value |
Set the required plotfile length in whole millimeters. The maximum length is limited to 3350mm. |
SWITCH POSITION 5 - Used Internally by Isogen
0 |
Generate a single byte format data file. |
1 |
Generate a multiple byte format data file. |