Controls how instrument name enclosures are plotted on the isometric drawing.

Switch Settings

The following settings are available for Option Switch 123:

SWITCH POSITION 1 - Balloon Type Enclosures

0

Plot no balloon enclosure around the instrument name.

1

Plot a balloon enclosure with 1 character maximum on each line.

2

Plot a balloon enclosure with 2 characters maximum on each line.

3

Plot a balloon enclosure with 3 characters maximum on each line.

4

Plot a balloon enclosures with 4 characters maximum on each line

5

Plot a balloon enclosure with 5 characters maximum on each line.

  • The diameter of the balloon enclosure is always generated at a size that will enclose the maximum number of characters set in Switch Position 5.

  • A maximum of two lines is allowed for balloon enclosures.

  • For a two-line name output, type the $ character in the name at the point where a new line is required.

SWITCH POSITION 2 - Not Used

SWITCH POSITION 3 - Instrument Enclosures

0

Use no enclosure.

1

Use a diamond-ended box enclosure.

2

Use a round-ended box enclosure.

3

Use a triangular-shaped enclosure (2 characters maximum).

4

Use a diamond-shaped enclosure (3 characters maximum).

5

Use a square-ended box enclosure.

6

Use a circular-shaped enclosure.

7

Use an elliptical-shaped enclosure.

8

Use a hexagonal-shaped enclosure.

  • Because triangular- and diamond-shaped enclosures (settings 3 and 4) cannot be elongated, there is a limit to the number of characters that can be accommodated.

  • If you use any of the box-type enclosures (settings 1, 2, and 5), you must set Switch Position 1 to 0.

  • For a two-line name output, type the $ character in the name at the point where a new line is required.

SWITCH POSITION 4 - Location Point (Message Enclosures)

0

Output the location point message preceded by a special text symbol.

1

Output the location point message in a square-ended box.

SWITCH POSITION 5 - Reference Names (Circular Enclosures)

0

Output reference names along steelwork reference lines.

1

Output one-character circular enclosure.

2

Output two-character circular enclosure.

3

Output three-character circular enclosure.

4

Output four-character circular enclosure.

5

Output five-character circular enclosure.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 10 - Instrument Balloon Facility

5.2.0

MAR 1987

7.0 Release Notes

7.0.0

Oct 1993

Related Option Switches

N/A

Option Switch Detail Sketch

Instrument ID Enclosure (OS 123)