Controls the following:
-
Automatic pipe splitting.
The amount of piping information that a single drawing can accommodate is limited. Once the limit is exceeded, then pipeline splitting automatically occurs. By using this option switch, you can either increase or decrease the information content on each drawing.
-
Format of drawing continuation messages.
-
Continuation graphics at the ends of spool isometric drawings.
Switch Settings
The following settings are available for Option Switch 38:
SWITCH POSITIONS 1, 2, and 3 - Drawing Information Content Limit
0 to 100 |
Use the default for what Isogen considers to be the limit for drawing information content. The limit is set within the software and varies for each size of drawing. This is the default setting. |
Value |
Increase or decrease the drawing information content by the specified amount in the ratio Value/100. |
SWITCH POSITION 4 - Drawing Continuation Message
0 |
Use standard drawing continuation message. |
1 |
Include the pipeline name in the drawing continuation message. |
2 |
Use PIPELINE-DRAWING-SEQUENCE-NUMBER (-90) in the drawing continuation message. |
3 |
Use CLIENT-DRAWING-IDENTIFIER (-92) in the drawing continuation message. |
4 |
Use SPOOL-DRAWING-SEQUENCE-NUMBER (-91) on the drawing continuation message. This setting applies only to spool isometric drawings. |
SWITCH POSITION 5 - Continuation at the Ends of Spool Drawings
0 |
Display continuation graphics on spool isometric drawings. |
1 |
Suppress display of continuation graphics on spool isometric drawings. |
Switch Layout
Related Program Development Specifications |
Version |
Date |
Introduced |
1.0.0 |
APR 1983 |
8.11.0 Release Notes |
8.11.0 |
APR 2003 |
8.13.0 Release Notes |
8.13.0 |
SEP 2006 |
9.0.0 Release Notes |
9.0.0 |
MAY 2008 |
Related Option Switches |
||
N/A |
||
Option Switch Detail Sketch |
||