Name |
User Name |
OA |
Category |
On Property Page |
Read Only |
---|---|---|---|---|---|
InsulLength |
Insulation Length |
Yes |
Dimensions |
Yes |
No |
InsulLengthRule |
Insulation Length Rule |
No |
Standard |
No |
Yes |
InsulationThickness |
Insulation Thickness |
Yes |
Dimensions |
Yes |
No |
InsulationThickness |
Insulation Thickness Rule |
No |
Standard |
No |
Yes |
InsulOffset |
Insulation Offset |
Yes |
Dimensions |
Yes |
No |
InsulOffsetRule |
Insulation Offset Rule |
No |
Standard |
No |
Yes |
InsulOffsetDef |
Insulation Offset Definition |
No |
Standard |
No |
Yes |
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhs_InsulLength:: |
Specifies the length of the insulation part. |
The default units are specified in the CustomInterfaces worksheet of the HS_S3DAssy workbook; otherwise, specify the units. For example, 200, 200mm, 20in. |
IJUAhs_InsulLengthRl:: |
Specifies the hgrSupportRule that returns the length of the insulation. The hanger rule must be the name of an existing rule in the catalog. To select the part number using InsulLength, do not specify any value for this property. |
For example: Rule Name: InsulLengthQtyByPipeDia Rule ProgID: HS_S3DRules.InsulLengthQtyByPipeDia |
IJUAhs_InsulationTh:: |
Specifies the thickness of the insulation. |
The default units are specified in the CustomInterfaces worksheet of the HS_S3DAssy workbook; otherwise specify the units. For example, 200, 200mm, 20in. |
IJUAhs_InsulationThRl:: |
Specifies the hgrSupportRule that returns the thickness of the insulation. The hanger rule must be the name of an existing rule in the catalog. To select the part number using InsulationThickness, do not specify any value for this property. |
For example: Rule Name: InsulThkQtyByPipeDia Rule ProgID: HS_S3DRules.InsulThkQtyByPipeDia |
IJUAhs_InsulOffset:: |
Specifies the offset for the insulation. If a clamp is available, the software bases the offset on the clamp position. If a clamp is not available, the software offsets other parts depending on the riser lug position. |
The default units are specified in the CustomInterfaces worksheet of the HS_S3DAssy workbook; otherwise specify the units. For example, 200, 200mm, 20in. |
IJUAhs_InsulOffsetRl:: |
Specifies the hgrSupportRule that returns the offset for the insulation. The hanger rule must be the name of an existing rule in the catalog. To select the part number using InsulOffset, do not specify any value for this property. |
For example: Rule Name: InsulOffsetOffsetByPipeDia Rule ProgID: HS_S3DRules.InsulOffsetOffsetByPipeDia |
IJUAhs_InsulOffsetDef:: |
Specifies the definition of the insulation offset and also determines how the attachment must be measured. If you set a value for InsulOffset, but do not specify a definition, the software displays an error message. |
1 - Offset from center of clamp/riser lug 2 - Offset bottom of insulation from lower edge of clamp/riser lug 3 - Offset top of insulation from upper edge of clamp/riser lug |