T Frame support uses all the General Attributes specified in Common Attributes section and the following additional general attributes:
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhsSupportNumber::SupportNumber |
The support detail number as specified on the support specification. This value will be used by the default BOM function when generating the BOM Description for the support. |
IE: TFrame-01 |
IJUAhsSteelStandard::SteelStandard |
A code list value that defines the steel standard used by the support. If external rules were written to select the steel standard, this attribute would be used to determine the standard to use. |
hsSteelStandard: 5 – Euro 10 – AISC 15 – CISC and so on. |
IJUAhsFrameType::FrameType |
A code list value that defines the type of the frame shape. |
hsFrameType: 1 - U Frame 2 - L Frame 3 - T Frame 4 - Split T Shaped Frame 5 - I Shaped Frame 6 - Vertical L Frame 7 - Box Shaped Frame 8 - Braced Box Shaped Frame 9 - Cantilever 10 - Braced Cantilever |
IJUAhsFrameConfiguration::FrameConfiguration |
Defines the initial frame configuration on placement. This property is applicable only to U, L and T-Frames types. You can change the configuration after placing the support by clicking Change Support Configuration on the ribbon. |
Accepted values are: 1 - Frame support placed on the far side of the pipe. 2 - Frame support placed on the closest side of the pipe. |
IJUAhsFrameOrientation:: FrameOrientation |
A code list value that defines the frame support orientation with respect to the supporting object or the global coordinate system. |
hsFrameOrientation: 1 - Direct towards the supporting object 2 - Orthogonal to the global coordinate system 3 - Tangent to the first and last selected pipes |
IJUAhsMirrorFrame:: MirrorFrame |
Mirrors the frame support about the bounding box. |
0 - False 1 - True |
IJUAhsIncludeInsulation:: IncludeInsulation |
Specifies whether the frame should adjust its size to include pipe insulation. |
0 - False 1 - True |
IJUAhsStructureConn:: StructureConnection |
A code list value that specifies how the hanger beam part is connected to the structure. |
1 - Normal 2 - Lapped 3 - Lapped-Opposite |
IJUAhsSuppPosOffset::SupPosOff |
Specifies the support distance from origin of the support. To determine the support position offset using SupPosOffRl, do not type any value for this property. |
|
IJUAhsSuppPosOffsetRl::SupPosOffRl |
Defines a HgrSupportRule that returns the support position offset. The hanger rule name or the ProgID must exist in the catalog. To determine the support position using SupPosOff, do not type any value for this property. |