Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhsFrPipeAtt1:: |
Specifies the part number or the part class of Pipe Attachment 1 on the first selected pipe. |
Pipe Attachment 1 is an optional part. To exclude a pipe attachment, do not enter any value for these attributes. |
IJUAhsFrPipeAtt1Rl:: PipeAtt1Rule |
Specifies a rule that returns pipe attachment part number. |
|
IJUAhsFrPipeAtt1Ang:: |
Specifies the angle of rotation about the route axis for Pipe Attachment 1. |
|
IJUAhsFrPipeAtt2:: |
Specifies the part number or the part class of Pipe Attachment 2. |
Pipe Attachments are optional parts. To exclude a pipe attachment, do not type any values for these attributes. |
IJUAhsFrPipeAtt2Rl:: PipeAtt2Rule |
Defines an HgrSupportRule that returns a pipe attachment part number. The hanger rule must exist in the catalog; it can be the rule name, or a ProgID. To select the part number using PipeAtt2Part, do not type any value for this property. |
|
IJUAhsFrPipeAtt2Ang:: |
Specifies the angle of Pipe Attachment 2. |
|
IJUAhsLugSupport:: |
Specifies the part number or the part class of a Lug support. |
LugSupport is an optional part. To exclude a Lug support, do not type any value for these attributes. |
IJUAhsLugSupportRl:: LugSupportRule |
An HgrSupportRule that returns a Plate Part-Number. The Hanger Rule should be present in the catalog; it can be the name of a rule, or a rule ProgID. If you intend to specify a Part-Number directly using LugSupport, then this attribute should be left blank. |
|
IJUAhsFrLug1Off:: IJUAhsFrLug1OffRl::Lug1OffRl |
Specifies the Lug offset (if applicable). |
The following definitions are supported: 1 - Normal 2 - (Offset by section depth) / 2 |
IJUAhsFrLug1OffDef::Lug1OffDef |
Defines how Lug1Offset is measured. |
Pipe Attachment 2 Attributes
Pipe Attachment 2 attributes display the same behavior as Pipe Attachment 1 attributes and are connected to the first selected pipe.